Primary links |
Over the years we have actively pursued Radcon treatments to structurally volatile sites having established up front that volatility was present.
These sites are usually under engineered car parks where vehicular loading is creating movement.
For these applications Radcon is the primary concrete waterproofing material and volatile cracks are addressed utilising an elastomeric in the cracks to accommodate movement without failure.